H13-629_V3.0試験無料問題集「Huawei HCIE-Storage V3.0 認定」
An enterprise plans to build three centers in two places on the cloud on HUAWEI CLOUD. The customer requires cross-regional disaster recovery to avoid business interruption. Due to the particularity of the business, the customer requires disaster recovery RPO=0. The technicians provided the customer with SDRS (Storage Disaster Recovery Service) + CBR (Cloud Backup and Recovery) solution of three center Y were built in Availability Zones 1 and 2 of region A, and the construction of region B. The remote disaster recovery center Z, X, and Z data centers can meet the customer's RPO=O disaster recovery requirements. 1. When all BBUs of the storage controller are damaged, the controller will automatically set the I/O write policy to write-through and lock to ensure data reliability. It cannot be forced to write-back before the fault is recovered.
正解:A
解答を投票する
An enterprise has established active-active data centers in city A and city B. If the active-active arbitration mode of storage (such as Huawei OceanStor hybrid flash memory) is static priority mode, site A is a static priority site. Which of the following descriptions are correct? (Multiple Choice)
正解:B,D
解答を投票する
LLD is based on the determined target network architecture, clearly design the scope of the network and function deployment plan, the specific design content includes clarifying the interaction process of important services concerned by customers within the scope of the contract, the function allocation of all services in each network element, design the surrounding interconnection relationship of network elements, interconnection requirements, compliance with specifications, and quantitative calculation of interconnection resources.
正解:B
解答を投票する
A customer's existing production environment server performance is relatively high, production network resources are relatively tight, and no snapshot license has been purchased for the generated storage. At present, the customer wants to introduce the backup service. Under the existing configuration, which backup networking method is recommended for the user?
正解:A
解答を投票する
( ) using the First Burst Enabled function of the SCSI protocol, the protocol-level optimization of data transmission between storage devices is performed, and the number of link transmission interactions for writing data is reduced by half.
正解:
FastWrite
Huawei pacific products can be used for content storage, backup and archiving scenarios. The obvious features of this scenario are real-time online business throughput ( ), frequent access to hot data, and data that needs to be stored for a long time. Online access needs are referenced.
正解:
large
In the scenario of database protection, when the slave side uses virtual snapshots to verify the LUN data consistency between the production side and the disaster recovery side, it is found that the database of the disaster recovery side LUN cannot be started normally. What are the possible reasons? (Multiple Choice)
正解:A,C,D
解答を投票する
The deployment process of the disaster recovery system in Huawei's active and standby disaster recovery solution is:
Solution networking
Synchronize data to the disaster recovery terminal
Deploy the disaster recovery management server on the disaster recovery terminal Configure protection groups and recovery plans Acceptance test
Solution networking
Synchronize data to the disaster recovery terminal
Deploy the disaster recovery management server on the disaster recovery terminal Configure protection groups and recovery plans Acceptance test
正解:B
解答を投票する